The SINAMICS G120X boasts smooth operation, affordability and energy efficiency, durability, dependability, and readiness for digitization. Suppliers and distributors have moved to New Delhi and Mumbai. It works with any standard motor (synchronous, induction, and synchronous reluctance) and is easy to incorporate into existing systems. Its adjustable operation can reduce costs and save resources, hence minimising the total cost of ownership. Bangalore and Pune are the top service providers for these goods.One of the top manufacturers of panels and providers of automation services in Mumbai, New Delhi, and Pune is Grups Automation.furthermore a provider and dealer of Siemens s71500 plc, ktp400 hmi, and VFD V20 components. Get these products in pune, chennai, and bangalore at reasonable costs.
MLFB | ITEM NAME |
---|---|
6SL32.0-.YE16-.U.0 | Sinomics G120X and Siemens VFD G120X 2.2 kW of rated power 100% 240 s, 110% 60 s Unfiltered 3 AC +10/-20% 47-63 Hz 380-480 V Temperature range: -20 to +45 °C Dimensions: FSA Protection level IP20 / UL open type |
6SL32.0-.YE18-.A.0 | Sinomics G120X and Siemens VFD G120X 3 kW of rated power 100% 240 s, 110% 60 s For category C2, radio interference suppression filter (380-480 V, 3 AC +10/-20%) 47-63 Hz Temperature range: -20 to +45 °C Dimensions: FSA Protection level IP20 / UL open type |
6SL32.0-.YE18-.U.0 | Sinomics G120X and Siemens VFD G120X 3 kW of rated power 100% 240 s, 110% 60 s Unfiltered 3 AC +10/-20% 47-63 Hz 380-480 V Temperature range: -20 to +45 °C Dimensions: FSA Protection level IP20 / UL open type |
6SL32.0-.YE20-.A.0 | Sinomics G120X and Siemens VFD G120X 4 kW of rated power 100% 240 s, 110% 60 s For category C2, radio interference suppression filter (380-480 V, 3 AC +10/-20%) 47-63 Hz Temperature range: -20 to +45 °C Dimensions: FSB Protection level IP20 / UL open type |
6SL32.0-.YE20-.U.0 | Sinomics G120X and Siemens VFD G120X 4 kW of rated power 100% 240 s, 110% 60 s Unfiltered 3 AC +10/-20% 47-63 Hz 380-480 V Temperature range: -20 to +45 °C Dimensions: FSB Protection level IP20 / UL open type |
6SL32.0-.YE22-.A.0 | Sinomics G120X and Siemens VFD G120X 5.5 kW of rated power 100% 240 s, 110% 60 s For category C2, radio interference suppression filter (380-480 V, 3 AC +10/-20%) 47-63 Hz Temperature range: -20 to +45 °C Dimensions: FSB Protection level IP20 / UL open type |
6SL32.0-.YE22-.U.0 | Sinomics G120X and Siemens VFD G120X 5.5 kW of rated power 100% 240 s, 110% 60 s Unfiltered 3 AC +10/-20% 47-63 Hz 380-480 V Temperature range: -20 to +45 °C Dimensions: FSB Protection level IP20 / UL open type |
6SL32.0-.YE24-.A.0 | Sinomics G120X and Siemens VFD G120X 7.5 kW of rated power 100% 240 s, 110% 60 s For category C2, radio interference suppression filter (380-480 V, 3 AC +10/-20%) 47-63 Hz Temperature range: -20 to +45 °C Dimensions: FSB Protection level IP20 / UL open type |
6SL32.0-.YE24-.U.0 | Sinomics G120X and Siemens VFD G120X 7.5 kW of rated power 100% 240 s, 110% 60 s Unfiltered 3 AC +10/-20% 47-63 Hz 380-480 V Temperature range: -20 to +45 °C Dimensions: FSB Protection level IP20 / UL open type |
6SL32.0-.YE26-.A.0 | Sinomics G120X and Siemens VFD G120X 11 kW of rated power 100% 240 s, 110% 60 s For category C2, radio interference suppression filter (380-480 V, 3 AC +10/-20%) 47-63 Hz Temperature range: -20 to +45 °C Dimensions: FSC Protection Level IP20 / UL Open Type |
6SL32.0-.YE26-.U.0 | Sinomics G120X and Siemens VFD G120X 11 kW of rated power 100% 240 s, 110% 60 s Unfiltered 3 AC +10/-20% 47-63 Hz 380-480 V Temperature range: -20 to +45 °C Dimensions: FSC Protection Level IP20 / UL Open Type |
6SL32.0-.YE28-.A.0 | Sinomics G120X and Siemens VFD G120X 15 kW of rated power 100% 240 s, 110% 60 s For category C2, radio interference suppression filter (380-480 V, 3 AC +10/-20%) 47-63 Hz Temperature range: -20 to +45 °C Dimensions: FSC Protection Level IP20 / UL Open Type |
6SL32.0-.YE28-.U.0 | Sinomics G120X and Siemens VFD G120X 15 kW of rated power 100% 240 s, 110% 60 s Unfiltered 3 AC +10/-20% 47-63 Hz 380-480 V Temperature range: -20 to +45 °C Dimensions: FSC Protection Level IP20 / UL Open Type |
6SL32.0-.YE30-.A.0 | Sinomics G120X and Siemens VFD G120X Power rating: 18.5 kW 100% 240 s, 110% 60 s For category C2, radio interference suppression filter (380-480 V, 3 AC +10/-20%) 47-63 Hz Temperature range: -20 to +45 °C Dimensions: FSD Protection level IP20 / UL open type |
6SL32.0-.YE30-.U.0 | Sinomics G120X and Siemens VFD G120X Power rating: 18.5 kW 100% 240 s, 110% 60 s Unfiltered 3 AC +10/-20% 47-63 Hz 380-480 V Temperature range: -20 to +45 °C Dimensions: FSD Protection level IP20 / UL open type |
6SL32.0-.YE32-.A.0 | Sinomics G120X and Siemens VFD G120X 22 kW of rated power 100% 240 s, 110% 60 s For category C2, radio interference suppression filter (380-480 V, 3 AC +10/-20%) 47-63 Hz Temperature range: -20 to +45 °C Dimensions: FSD Protection level IP20 / UL open type |
6SL32.0-.YE34-.A.0 | Sinomics G120X and Siemens VFD G120X 30 kW of rated power 100% 240 s, 110% 60 s For category C2, radio interference suppression filter (380-480 V, 3 AC +10/-20%) 47-63 Hz Temperature range: -20 to +45 °C Dimensions: FSD Protection level IP20 / UL open type |
6SL32.0-.YE34-.A.0 | Sinomics G120X and Siemens VFD G120X 30 kW of rated power 100% 240 s, 110% 60 s For category C2, radio interference suppression filter (380-480 V, 3 AC +10/-20%) 47-63 Hz Temperature range: -20 to +45 °C Dimensions: FSD Protection level IP20 / UL open type |
6SL32.0-.YE34-.U.0 | Sinomics G120X and Siemens VFD G120X 30 kW of rated power 100% 240 s, 110% 60 s Unfiltered 3 AC +10/-20% 47-63 Hz 380-480 V Temperature range: -20 to +45 °C Dimensions: FSD Protection level IP20 / UL open type |
6SL32.0-.YE36-.A.0 | Sinomics G120X and Siemens VFD G120X 37 kW of rated power 100% 240 s, 110% 60 s For category C2, radio interference suppression filter (380-480 V, 3 AC +10/-20%) 47-63 Hz Temperature range: -20 to +45 °C Dimensions: FSD Protection level IP20 / UL open type |
6SL32.0-.YE36-.U.0 | Sinomics G120X and Siemens VFD G120X 37 kW of rated power 100% 240 s, 110% 60 s Unfiltered 3 AC +10/-20% 47-63 Hz 380-480 V Temperature range: -20 to +45 °C Dimensions: FSD Protection level IP20 / UL open type |
6SL32.0-.YE38-.A.0 | Sinomics G120X and Siemens VFD G120X 45 kW of rated power 100% 240 s, 110% 60 s For category C2, radio interference suppression filter (380-480 V, 3 AC +10/-20%) 47-63 Hz Temperature range: -20 to +45 °C Dimensions: FSE Protection level IP20 / UL open type |
6SL32.0-.YE38-.U.0 | Sinomics G120X and Siemens VFD G120X 45 kW of rated power 100% 240 s, 110% 60 s Unfiltered 3 AC +10/-20% 47-63 Hz 380-480 V Temperature range: -20 to +45 °C Dimensions: FSE Protection level IP20 / UL open type |
6SL32.0-.YE40-.A.0 | Sinomics G120X and Siemens VFD G120X 55 kW of rated power 100% 240 s, 110% 60 s For category C2, radio interference suppression filter (380-480 V, 3 AC +10/-20%) 47-63 Hz Temperature range: -20 to +45 °C Dimensions: FSE Protection level IP20 / UL open type |
6SL32.0-.YE40-.U.0 | Sinomics G120X and Siemens VFD G120X 55 kW of rated power 100% 240 s, 110% 60 s Unfiltered 3 AC +10/-20% 47-63 Hz 380-480 V Temperature range: -20 to +45 °C Dimensions: FSE Protection level IP20 / UL open type |
6SL32.0-.YE42-.A.0 | Sinomics G120X and Siemens VFD G120X 75 kW of rated power 100% 240 s, 110% 60 s For category C2, radio interference suppression filter (380-480 V, 3 AC +10/-20%) 47-63 Hz Temperature range: -20 to +45 °C Dimensions: FSF Protection level IP20 / UL open type |
6SL32.0-.YE42-.U.0 | Sinomics G120X and Siemens VFD G120X 75 kW of rated power 100% 240 s, 110% 60 s Unfiltered 3 AC +10/-20% 47-63 Hz 380-480 V Temperature range: -20 to +45 °C Dimensions: FSF Protection level IP20 / UL open type |
6SL32.0-.YE44-.A.0 | Radio interference suppression filter for category C2 380-480 V 3 AC +10/-20% 47-63 Hz Ambient temperature -20 to +45 °C Size: FSF Degree of protection IP20 / UL open type Siemens VFD G120X, Sinomics G120X Rated power: 90 kW At 110% 60s, 100% 240 s |
6SL32.0-.YE44-.U.0 | Sinomics G120X and Siemens VFD G120X 90 kW of rated power 100% 240 s, 110% 60 s Unfiltered 3 AC +10/-20% 47-63 Hz 380-480 V Temperature range: -20 to +45 °C Dimensions: FSF Protection level IP20 / UL open type |
6SL32.0-.YE46-.A.0 | Sinomics G120X and Siemens VFD G120X 110 kW of rated power 100% 240 s, 110% 60 s For category C2, radio interference suppression filter (380-480 V, 3 AC +10/-20%) 47-63 Hz Temperature range: -20 to +45 °C Dimensions: FSF Protection level IP20 / UL open type |
6SL32.0-.YE46-.U.0 | Sinomics G120X and Siemens VFD G120X 110 kW of rated power 100% 240 s, 110% 60 s Unfiltered 3 AC +10/-20% 47-63 Hz 380-480 V Temperature range: -20 to +45 °C Dimensions: FSF Protection level IP20 / UL open type |
6SL32.0-.YE48-.A.0 | Sinomics G120X and Siemens VFD G120X 132 kW of rated power 100% 240 s, 110% 60 s For category C2, radio interference suppression filter (380-480 V, 3 AC +10/-20%) 47-63 Hz Temperature range: -20 to +45 °C Dimensions: FSF Protection level IP20 / UL open type |
6SL32.0-.YE48-.U.0 | Sinomics G120X and Siemens VFD G120X 132 kW of rated power 100% 240 s, 110% 60 s Unfiltered 3 AC +10/-20% 47-63 Hz 380-480 V Temperature range: -20 to +45 °C Dimensions: FSF Protection level IP20 / UL open type |
6SL32.0-.YE50-.A.0 | Sinomics G120X and Siemens VFD G120X 160 kW of rated power 100% 240 s, 110% 60 s For category C2, radio interference suppression filter (380-480 V, 3 AC +10/-20%) 47-63 Hz Temperature range: -20 to +45 °C Dimensions: FSG Protection level IP20 / UL open type |
6SL32.0-.YE50-.C.0 | Sinomics G120X and Siemens VFD G120X 160 kW of rated power 100% 240 s, 110% 60 s For category C3, radio interference suppression filter 380-480 V 3 AC +10/-20% 47-63 Hz Temperature range: -20 to +45 °C Dimensions: FSG Protection level IP20 / UL open type |
6SL32.0-.YE52-.A.0 | Sinomics G120X and Siemens VFD G120X 200 kW of rated power 100% 240 s, 110% 60 s For category C2, radio interference suppression filter (380-480 V, 3 AC +10/-20%) 47-63 Hz Temperature range: -20 to +45 °C Dimensions: FSG Protection level IP20 / UL open type |
6SL32.0-.YE52-.C.0 | Sinomics G120X and Siemens VFD G120X 200 kW of rated power 100% 240 s, 110% 60 s For category C3, radio interference suppression filter 380-480 V 3 AC +10/-20% 47-63 Hz Temperature range: -20 to +45 °C Dimensions: FSG Protection level IP20 / UL open type |
6SL32.0-.YE54-.A.0 | Sinomics G120X and Siemens VFD G120X 250 kW of rated power 100% 240 s, 110% 60 s For category C2, radio interference suppression filter (380-480 V, 3 AC +10/-20%) 47-63 Hz Temperature range: -20 to +45 °C Dimensions: FSG Protection level IP20 / UL open type |
6SL32.0-.YE54-.C.0 | Sinomics G120X and Siemens VFD G120X 250 kW of rated power 100% 240 s, 110% 60 s For category C3, radio interference suppression filter 380-480 V 3 AC +10/-20% 47-63 Hz Temperature range: -20 to +45 °C Dimensions: FSG Protection level IP20 / UL open type |
6SL32.0-.YH18-.A.0 | Sinomics G120X and Siemens VFD G120X 3 kW of rated power 100% 240 s, 110% 60 s Category C2 radio interference suppression filter, 500–690 V 3AC +10––20% 47–63 Hz Temperature range: -20 to +45 °C Dimensions: FSD Protection level IP20 / UL open type |
6SL32.0-.YH18-.U.0 | SIEMENS VFD G120X, SINAMICS G120X Rated power: 3 kW At 110% 60s, 100% 240 s Unfiltered 500-690 V 3AC +10/-20% 47-63 Hz Ambient temperature -20 to +45 °C Size: FSD Degree of protection IP20 / UL open type |